No heat, short bursts of heat, or a furnace that lights and then gives up. A licensed technician diagnoses it for $89 and quotes the repair before touching anything.

At a glance

Diagnostic fee
$89
Typical total
$220 – $450
Usual response
Same day
On site
1 – 2 hours

Work warranted 12 months

If you smell gas, leave the building first and call the gas company from outside. Do not wait for a technician, and do not use a light switch or phone indoors on the way out.

What we usually find

Runs for a minute, then shuts off

Classic dirty flame sensor. The furnace lights, fails to confirm the flame, and shuts down for safety. It is one of the cheapest faults in heating and one of the most common calls in January.

$220 – $380 typical

Blower runs but the air is cold

Often a failed ignitor or a gas valve that is not opening. Sometimes it is only a thermostat set to FAN rather than AUTO, which costs nothing to check first.

$250 – $600 typical

Nothing happens at all

A tripped breaker, a blown low-voltage transformer, a safety switch on a full condensate pan, or a door switch left open after a filter change.

$180 – $550 typical

Heat pump running constantly in the cold

Below about 35°F a heat pump leans on auxiliary heat, and a failed defrost board or reversing valve makes it run without ever catching up. Expensive to ignore — the strip heat is what your bill notices.

$350 – $1,400 typical

A bang or boom when it lights

Delayed ignition — gas pooling before it catches. Treat this as urgent rather than annoying: it stresses the heat exchanger, and a cracked exchanger is a carbon monoxide problem, not a comfort one.

$250 – $900 typical

Some rooms warm, others freezing

Usually airflow rather than the furnace: a blocked return, a closed damper, or undersized ductwork in a converted upper floor. Common in DC rowhouses split into units.

$180 – $1,200 typical

Try these first — they’re free

Genuinely. Three of these fix the problem often enough that we’d rather tell you than take your $89.

  1. 01Check the thermostat is on HEAT, set above room temperature, and has working batteries
  2. 02Change the filter — a clogged one trips the high-limit switch and shuts the furnace down
  3. 03Make sure the furnace door panel is fully seated; the safety switch behind it cuts power
  4. 04Check the breaker and the switch on the wall by the unit, which looks like a light switch and gets flipped by accident

Still not sorted?

Request in the app and a verified company usually accepts within a few minutes.